Re: [DML] Fan Blower Only #4 works
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [DML] Fan Blower Only #4 works
- From: dherv10@xxxx
- Date: Wed, 3 Apr 2002 22:17:47 EST
Jason, Blower motor speed on 1 and 2 work straight off the switch and through
the resistance wire.. Then voltage for 3 and 4 comes through the circuit
breaker and the 3 and 4 work off their own relay's and again feeds throght
the resistance wires. So the first thing i would check is the blower motor.
Hook it up to 12 volts and see if it turns easy. The if it does, see if the
resistance wires are ok. Easy to come out and look. Last, what voltage do you
have going to the blower motor. If you have only 10,11, volts. It won't turn
briskly. Low battery or alternator voltage.
John hervey
<< I have been reading some past posts about the internal heater/AC
blowers however I did not seem to find some solid answers. It seems
like my D's blower motor only works on the highest level 1, 2 and 3
do not seem to work and 4 is nothing to scream about. Has any one
had any similar problems with a fix? Or maybe where to suggest to
look 1st?
>>
Back to the Home of PROJECT VIXEN