Re: [DML] Fuse #5 blowing
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [DML] Fuse #5 blowing
- From: "Louie" <louie@xxxxxxxxxxxx>
- Date: Tue, 18 Oct 2005 19:01:05 -0000
Thanks for all the help on this problem guys! It turned out one of the
wires to the temperature switch had hit the exhaust manifold and was
melted. I would have never guessed to look back there because the
manual says nothing about #5 powering the temperature switch. Oddly
enough it looks like this might have happened before to my car... the
same wire that was melted has a different connecter than the second
wire. The car is running great now though, just in time for this great
fall weather!
Louie Golden
VIN 5252 Charlotte, NC
--- In dmcnews@xxxxxxxxxxxxxxx, "John Hervey" <john@xxxx> wrote:
>
> Louie, You might look around the otterstat, #5 powers that also and
if the
> wire hit the exhaust manifold there would be the short.
> John Hervey
To address comments privately to the moderating team, please address:
moderators@xxxxxxxxxxx
For more info on the list, tech articles, cars for sale see www.dmcnews.com
To search the archives or view files, log in at http://groups.yahoo.com/group/dmcnews
Yahoo! Groups Links
<*> To visit your group on the web, go to:
http://groups.yahoo.com/group/dmcnews/
<*> To unsubscribe from this group, send an email to:
dmcnews-unsubscribe@xxxxxxxxxxxxxxx
<*> Your use of Yahoo! Groups is subject to:
http://docs.yahoo.com/info/terms/