Re: [DML] Stalls after starting
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [DML] Stalls after starting
- From: elvisnocita@xxxx
- Date: Mon, 23 Jun 2003 12:17:01 +0200 (MEST)
check your idle speed motor it may be stuck closed and during startup it
needs to open a little more to keep running. When warm idle may be fast enough
to keep running.
Or is the micro switch working ? Is it really being pushed ?
If it bounces like you describe it may also be a bad vacuum leak or the
O2-Sensor may be sending wrong informations because it still isn't warmed up.
There's a temp-sensor which tells the system to set the PWM of the buzzing valve
on the right valve-cover to work with a constant PWM until the system is
warm enough. So the first few minutes the PWM should not vary. I would suggest
to check this first.
Informations how to do this can be found on the DMCNEWS site or anywhere
else on the web.
Elvis
> Howdy. I have two D's and one runs like a top and one has this
> problem. I starts right up but unless I keep my foot on the gas it
> stalls out.