In general I disapprove of just replacing parts blindly. A complaint
of no #4 fan speed could be caused by too many things from a defective
fan speed switch to a wire not connected to a missing relay to a burnt
connecter to the relay. You really have to do a little troubleshooting
to try to narrow down the source of the problem. I think I would start
by pulling the #4 speed relay and checking the wiring and if the
proper voltages are present. You could also jump out the relay with a
paper clip to verify power and wiring to the fan motor. With a test
light or a meter you can make sure the fan speed switch is OK. On an
older car you can never take anything for granted. I just read how
someone bought a car in an auction and after buying it tried the
wipers. Not only didn't they work but there was no motor or
linkage! The wipers were just bolted on!
David Teitelbaum
vin 10757
--- In dmcnews@xxxx, shain@xxxx wrote:
> Jason,
>
> Not to question DMCJoe, i had a similar problem on my car. The
ground wires on the relays for the fan speed had burnt very heavly on
my car, and along with a bad relay i was having a similar problem.
New wire and a relay (replace the relays is a good idea, the fan speed
is one of the most used relays in the car)and it works now.
>
> - Shain
> #10140
>
> ----- In Response To -----
>
> Jason,
>
> Replace the Fan Speed Resistor Part#101275 (parts manual 7/1/0 fig.)
our
> price is $26.56.
>
> Regards,
> DMC Joe/Help Club dmchelp@xxxx
> Information & Store http://shopping.oraclesmallbusiness.com/dsvstore
> DeLorean Website Directory www.dmc.tv
> 770 631-4800
>
> ----- Original Message -----
> From: "jason3625" <jason@xxxx>
> To: <dmcnews@xxxx>
> Sent: Wednesday, April 03, 2002 3:15 PM
> Subject: [DML] Fan Blower Only #4 works
>
>
> > I have been reading some past posts about the internal heater/AC
> > blowers however I did not seem to find some solid answers. It
seems
> > like my D's blower motor only works on the highest level 1, 2 and
3
> > do not seem to work and 4 is nothing to scream about. Has any one
> > had any similar problems with a fix? Or maybe where to suggest to
> > look 1st?
> >
> >
> > Thanks
> >
> > Jason
>
>
>
>
> To address comments privately to the moderating team, please
address:
> moderator@xxxx
>
> To search the archives or view files, log in at
http://groups.yahoo.com/group/dmcnews
>
> Your use of Yahoo! Groups is subject to
http://docs.yahoo.com/info/terms/
>
>
>
>
>
> -----------------------------------
> WSMMail Brought to you by Adgrafix!
> http://www.adgrafix.com
Back to the Home of PROJECT VIXEN