Jim, If things are working properly and all connections are tight, both fans
will draw about 28 to 30 amps. This depends on how many miles are on the fan
motors. I took mine apart and rebuilt them, clean, oil, new brushes and they
now draw about 11-12 amps ea under full load. My new fan fail jumper is now
fused at 15 amps on ea leg and they just barely heat. That's what you want. I
try not to over fuse or you loose protection. With 25 amps per leg, you
might as well wire them direct.
John Hervey