Re: [DML] Loading R12 in A/C system
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [DML] Loading R12 in A/C system
- From: "Tom Niemczewski" <tomcio@xxxx>
- Date: Sun, 30 Jul 2000 23:58:22 +0200
First a vacuum pump should be used to remove air and moisture from the
system. It takes about 20 to 30 minutes. Then he should charge the system
with 2.2 lbs of R-12. No A/C system will turn the compressor on without
proper pressure. May I suggest that you stay away from that mechanic? He has
no idea how the A/C system works.
Hope this helps.
Tom Niemczewski
tomcio@xxxx
vin 6298
----- Original Message -----
> Last week, we changed the A/C compressor's seals to get it air tight.
>
> When completed, we brought the car to an A/C shop to replenish on R12 (I
know it is expensive...)
> But after trying to load the gaz, the mechanic stopped because the
compressor would not start, and he could not mesure the pressure without the
compressor starting...
>
> The problem is that the compressor would not work without gaz pressure...
So the mechanic refused to replenish the system!
>
>
> So what is the usual procedure to load R12 gaz after you emptied the
system?
>
>
> François Laplante
> VIN: 17145